Abstract:This article introduces the application of PZ96L and AMC96L in Vietnam photovoltaic inverters. Right now, grid companies usually require photovoltaic grid-connected systems to be irreversible , that is, the electricity generated by photovoltaic grid-connected systems is consumed by local loads, and excess electricity is not allowed to supply to the grid. The system can regulate power generation in order to prevent the photovoltaic grid-connected system from generating reverse power.
1.Project Overview
The photovoltaic power generation company in Vietnam, after confirming that our company's PZ96L and AMC96L protocols can be connected to their current solar inverters, they chose to purchase these two models as the electricity statistics of the photovoltaic AC part to ensure that the electricity generated by photovoltaic will not be sent to the state grid.
Solution for PV anti-backflow
Solution for PV DC coupled energy storage
Solution for photovoltaic AC coupled energy storage
2.Product Selection
Anti-reflux
Application | Model | Certificate | Product |
Single phase | AGF-AE-S | ANSI C12 | |
ACR10R-D10TE | CE | ||
Two phase | AGF-AE-D | ANSI C12 UL 1741 | |
Three phase | ACR10R-D10TE4 | CE | |
PZ96L | CE |
Functions
1) Measure power generation and the use of electricity,
2) Data refresh rate: 250ms,
3) Split core CT, 300A current,
4) Communication: RS485 and grid-connected inverter or energy storage inverter
Certificate
AGF-AE-D
ACR10R
PZ Series electric energy meters, adopting AC sampling technology, can measure many three phase grid electrical parameters such as current, voltage, power, electric energy etc. directly or indirectly. It may be used for local display, and connected with the control equipment to form measuring and controlling system. Fitted with RS-485 communication port, adopting compatible Modbus-RTU protocol, meters can switch electric parameter signal into standard analog output, with four-channel (two-channel) switching input / two-channel switching output.
Based on different requirements, by keys on the faceplate, electric parameters for transformation ratio, alarm, communication etc. can be set up and controlled. PZ series meters have extra high price performance ratio, can simply replace traditional electric transducer and measuring meters.As an advanced intelligent, digital front end acquisition component, this electric meters have widely used in various control system, SCADA system and energy source management system.
DJSF1352-RN DC Energy Meter
Functions:
1) Accuracy: 1, voltage output: ±12V
2) Communication: infrared and RS485 communication, Modbus-RTU and 645 protocol
3) DIN rail installation
4) Support hall sensor or shunt input
3.Centralized PV solutions
In the solar PV power generation system, the smart PV combiner box reduces the connection between the solar PV cell array and the inverter. The box can monitor the operating status of the solar panels, lightning protector and DC circuit breaker. With RS485 interface, the device can upload the measured and collected data and equipment status.
4.Product Selection
Name | Product |
Combiner box | |
PV Confluence Acquisition Device |
1.AGF Series Confluence Acquisition Device
Functions
1) Current specification: 20A, perforation connection;
2) 3 DI; Temperature measurement;
3) Busbar voltage measurement: DC 1500V;
4) LCD display.
Certificate
2.APQM Power Quality Monitoring Device
Functions
1) Measurement of electrical parameters, harmonics, inter-harmonics, voltage fluctuation, flicker,
2) Monitoring of voltage swell, voltage sag, voltage interruption,
3) Statistics of power quality limit times, voltage qualification rate, and form the report.